Acid Water Ionizer:+86-535-6589929
Alkaline Water Ionizer:+86-535-6589928
In 1990,Japan iron and steel department develop the electrolyzed water technology to prolong the rice expire date and JIPCM company succeed with it and better it that the main method is killing bacteria to prolong the expire date.The further research of the disinfect of electrolyzed water make this technology skilled and dependable.
According to that,our engineers in China develop more purposes in industrial application domain alike degreased cleaning,silicom water relative cleaning,solar energy silicon wafer,circuit board cleaning and tableware cleaning in kitchen.
1.water electrolyzed cutting fluid
(1) Water is electrolyzed by direct current leading to generate the alkaline water from positive electrode and the acidic water from negative electrode.
(2) Who has invented the water electrolyzed cutting fluid?
Engineer in Frank Aug.2012 attempt to mix in proportion with alkaline electrolyzed water PH value 10.5 and basic oil to become water electrolyzed cutting fluid.this is the new proportional cutting oil in metal processing industry by acquiring inquiry center in Shenzhen.This fluis is of new type green environmental scheme for super rigid and super strong metal processing.meanwhile,the water electrolyzed cutting fluid has the best stability not including superficial acitive agent,anti-rust agent,boron,chlorine and nitrite and soon.
3.the technological advantage of water electrolyzed cutting fluid
The advantage of that in compare with ordinary industrial traditional processing fluid with water shows:
(1)Good anti-rust
(2)Good settlement ability
(3)Lower the liquid water cost because of no disinfect with amine.
(4)Non.odor,prolong 1 time using time compared with the traditional.
(5)Non greasy dirt,non oil mist non harm and cleaning working surrounding.
(6)Rapidly take heat away and fully cool the cutter tool to protect it without cleaning and degreasing.
(7)Super long using time about 5 years.
2.detergent of electrolyzed water
(1)The character of detergent
(2)Frank’s research group find that PH value 11.5 electrolyzed water directly applies into the industrial cleaning in place of the chemical detergent.
Here is the principle showed the super cleaning for electrolyzed water:
a.Alkaline diffusing function
Alkaline electrolyzed water can decompose grease to alkalize glycerol and fatty acid salts in benefit with surface active effect and remove grease dirt.
B.floating function
The dirt attached with the object has the strong negative charge which is repulsive with the negative charge in electrolyzed water in order to remove out.this repulsion has the effect of re-pollution.
C.removing function of soluble hydrogen
Electrolyzed water has much soluble hydrogen element in order to remove the dirt.
d.PH value function
Metal surface generate non dynamic phenomenon over PH value 10 in order to avoid from corrosion.
e.low dissolved oxygen function
In compare with water,the number of the dissolved oxygen lower by 50% in electrolyzed water.it leads to corrode.
Electrolyzed water has strong alkalineto refrain the development of non dynamic membrane on the surface of metal.
f.anti-rust function
SPCC test samples separately put into running water and electrolyzed water.Just inspect the rusting process on the
surface of sample.the surface of sample is intact.
g.degreasing function
Degreasing and cleaning of electrolyzed water
Cleaning object:SPCC
Die casting parts
Cleaning temperature:40 degree(ethylene in room temperature)
Attached oil:mineral oil DP-15
Cleaning time and way:3 minutes,ultrasonic 28KHZ 300W
Test way: oil determination of hexane extraction method
Conclusion:electrolyzed water has the excellent degreasing ability.
2.the application of water electrolyzed detergent
Be adjusted with the liquid-crystal glass,optical glass and silicon wafer.
Apply with the stainless steel,alloy and cast iron parts in automobile industry.